HC line – Trench heater line with cooling option

  • stainless steel body
  • high heating and cooling performance of forced convection
  • heats even when the fan is off
  • rapid heating/cooling of the room
  • safe voltage 24 V EC
  • electronically commutated (EC) fan motor
  • wide options of setting the microprocessor control unit
  • suitable for a heat pump
  • wide size range
  • AIR version - connection to HVAC

Function

with a fan

heating

cooling

ventilation

dry environment

heat pump

Dimensions

200 / 260 / 340 mm

110 / 150 / 185 mm

900 - 3000 mm

3860  |  1228  W/m
Inquire
Contact form
Name (Optional)
Last name
E-mail
Phone Number
Message
By submitting you agree to the processing of personal data pursuant to Act No. 101/2000 Coll. on the Protection of Personal Data.
Submit form

Technical parameters

Input parameters for calculation

Heating
Cooling

Length (mm)

Atypical length (mm)

Width x height (mm)

Inlet water temperature

Outlet water temperature

Interior temperature (°C)

Inlet water temperature

Outlet water temperature

Interior temperature (°C)

Output parameters

Q [W]
Performances
q [l/h]
Water flow
∆P [kPa]
Water pressure drop
V [l]
Heat exchanger water volume
Enter input parameters
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.

Available grilles and accessories

Grille- aluminium

rolling - dense

Grille - wood

rolling - dense

Grille - st. steel

rolling - dense (must be ordered with the convector)

Frame

standard

Frame

covering

Grille - wood - transverse

shade: OAK

Grille - wood - transverse

shade: MAPLE

Grille - aluminium - transverse

shade: LIGHT BRONZE

Grille - st. steel - transverse

shade: ST. STEEL

Grille - aluminium - transverse

shade: SILVER

Grille - wood - transverse

shade: BEECH

FROM SOLUTION PROPOSALS TO IMPLEMENTATION ASSISTANCE

Can we help your project?

Take advantage of our years of experience and involve us to your project. We will advise you on the most suitable choice of heating and cooling system, we also conduct our own measurements and discuss with the contractor the ideal way of installation.

Save up to 50% on heating

CONVECTORS -

THE MOST ECONOMICAL HEATING SOLUTION TO A HEAT PUMP 

More here »